jacobs

 

geofutura logo

 

Generated by ManHole reporting system made by 

Project: A127 Fairglen Junction

Client Name Essex Highways
Project Name Blue Roundabout - Harwich
Project Number 9999
Report Type Manhole Record Survey
Created Date 7 May 2017
Created By Howard Zabell
link to project http://trackRecord

 

At Jacobs, our focus on building long-term client relationships has helped us become one of the largest and most diverse companies in our industry. Today, our more than 70,000 employees around the world provide a broad range of technical services to our industrial, commercial and government clients in multiple industries.

Our global network includes more than 250 offices in more than 28 countries. We have operations in North America, South America, Europe, the Middle East, India, Australia, Africa, and Asia. With 2013 revenues of $11.8 billion, we offer full-spectrum support to industrial, commercial, and government clients. Services include scientific and specialty consulting, as well as all aspects of engineering, architecture, construction, program & construction management, and operations & maintenance.

 

  MANHOLE INFORMATION
Manhole number MH BR1
Manhole Red 666
Manhole Coordinates X,Y,Z
Grid Reference No answer
Manhole Service Type Service Water
Surveyor HZ
Assistant MB
Time of surveying 22:00:00
Measuring Tools Tape
Man Entry? No
Access Type Ladder
   
   
   
   
   
   
   
   

space

Manhole Cover Information
19. Damage No
20. Cover Duty Light
21. Cover Shape Square
22. Cover Material Steel
23. Padlocked No
24. Manhole Cover Size 0.65m x 0.65m
25. Manhole Cover Level 1.38m

space

 Manhole Shaft / Chamber Information
24. Shaft Dimensions 0.60m x 0.59m
25. Shaft Material Brick
26. Shaft Condition Good
27. Depth to U/S Biscuit 0.48m
28. Reduced Biscuit Level 0.90m
29. Biscuit Material Concrete
30. Slab / Taper Slab
31. Chamber Dimensions 1.05 m dia
32. Chamber Material Concrete
33. Chamber Condition Good
34. Water Level N/A
35. Silt Level 1.78m
36. Sump Level N/A
37. Toxic Atmosphere No

space

Incoming Pipes
1. Pipe 2. Status 3. Cover depth to Invert 4. Reduced Invert Level 5. Pipe size 6. Pipe Materials 7. Connection 8. Connection proven by
               
               
               
               
Outgoing Pipes
 1. Pipe  2. Status  3. Cover depth to Invert  4. Reduced Invert Level  5. Pipe size 6. Pipe Materials   7. Connection  8. Connection proven by
               
               

Sketch

 

PHOTOS:

 

Comments and additional information’s: